Technical Specifications

 

 

Technical Director:   Lou Manganello         (775) 686-6620

                                                                        loum@pioneercenter.com

Technical Manager:              Italo Crocco               (775) 686-6140

                                                                        Italoc@pioneercenter.com

 

(775) 686-6630 FAX

                                                                       

House Size

Orchestra Seating  975  (There are 38 seats that can be removed to make 14 wheelchair locations.  There are also 16 transfer seats available.  These are in addition to the wheelchair only seats described below.)

Wheelchair Only     12 (No physical seats present, space for wheelchairs or folding chair for companion.  Located at rear of the Orchestra, Sections A and E, Row V.)

Orchestra Total       987

Balcony Total          513

Total Capacity         1500

 

 

Important items of note:

Stage is located 22’-6” below street level. Access to stage is down 2 flights of stairs.  All dressing rooms are at stage level, as are the green room, production room, shop, and staging areas.  House Technical Service office and Workshop are located above dressing rooms.  Technical/Facility Director’s office is located lower lobby, north side of theatre.

 

Parking Restrictions:

Pioneer Staff Parking Only! is located adjacent to the Freight Elevator.  Load-in and Load-out will be scheduled according to rider requirements.  All other parking (such as buses, trailers, vehicles, etc.) must be on street perimeters.  Meters will be bagged accordingly when required by rider, please contact the Technical Director at least 48 before load in to ensure sufficient parking.  The Pioneer Center does not take responsibility for any parking or traffic tickets that you or your company may encounter during your engagement.  This includes rehearsals.  Unauthorized vehicles parked in staff lot will be towed at owner’s expense!

 

Local Truck Stops

Boomtown:              (800)648-3790

Alamo:                       (775)355-8888

 

Phone Numbers:

            Administration Office                        775-686-6610

Administration Fax                            775-686-6630

Production Phone/Fax                      775-686-6145

Production Phone/Fax                      775-786-5254

Ticket Office                                      775-686-6600

Technical Manager                           775-686-6140

Technical Director                             775-686-6620

The front production office and Green Room have high-speed internet access.       


 

Stage Information

 

Floor:                Level maple hardwood sprung dance floor. 68’ in width and 44’ in depth from downstage edge to back wall, 38’-11” plaster line to back wall. Back and side walls of stage slope inward at 7ْ  angle from floor to grid. 

Orchestra Pit: Manually set at three different levels: “FULL” = Level with Stage Floor, “HALF” = 3’-8” below Stage Level, or “OUT” = 7’-6” below Stage Level. Pit front arcs 13’-6” at center to flush at the sides.  Access is down one flight of stairs by dressing rooms. Limited storage is available at lower pit level.

            The back wall of the stage slopes inward at 7ْ

Measurements:

Proscenium:              49’-8”              Wide

                                    23’-11”            High

Depth:                         37’-6”              Curtain line to Back wall

44” -0”             Down Stage Edge to Back wall

6’-6”                Cross-Over behind last line set

Width:                         48’-7”              Centerline to Offstage Left Wall

50’-7”              Centerline to Offstage Right Wall

                                    Apron Depth:             6’-0”                At Centerline

                                                                        7’-0”                At Proscenium

                                    Stage to Grid:            60’-8”              Top of Steel  

                                                                        59’-8”              Clearance under Battens

Stage to Fly rail:        20’-2”

Fly rail to Grid:           40’-6”

Lower Ceiling to Pit: 31’-10”            Pit at full

House Curtains:

Main Curtain              66’ Wide x 26’ High

Main Valance            66’ Wide x 12’ High

Black Legs                 12’ Wide x 28’ High        (2 sets)

                                    14’ Wide x 28’ High        (2 sets)

Black Borders           60’ Wide x12’ High         (2 available)

                                    60’ Wide x 14’ High        (2 available)

Blackout Curtain        30’ Wide x 36’ High        (2 panels)

                                    (May be rigged as a traveler)

 

 

                    Load In:        Access to stage is by Freight Elevator, 9’-2”  Wide X 21’ Long X 12’ High.  Load Capacity is 11,500 lbs.  Elevator will raise to truck height, unloads into staging area off stage left. 

                                                No vehicles allowed on Elevator!                                             

                                                Access to stage is thru doors 10’ Wide x 12’ High.  

 

 


 

Lights and Sound

 

Lighting Information          (All distances are from Plaster Line):

Control Booth located at Orchestra, level 94’ (4ْ  )

Follow spot booth located at Balcony, level 100’ (22ْ  )

Balcony Rail, 60 ft. at center (15ْ  )

FOH AP (ceiling cove), 45‘at center (50ْ  )

Back Row of Orchestra, 93‘

Front Row of Balcony, 64’

 

Console:                   Expression 2X version 3.2 (with Remote Focus Unit + Monitors)

Dimmers:                  192 Kliegl K96 2.4kw – DMX Input

Instruments:            26- Source Four 575w (with 26ْ  lenses, 12 extra 36ْ  lenses, and 4 19 ْ lenses )

22- Altman Shakespeare 575w (20ْ  lenses)

12- Century 8 inch Fresnel 1000w

6- Berkey-Colortran 6 inch Fresnel 750w

9-Altman 4 Circuit Zip Strips EYC (40ْ  ) @ 750w per circuit

6-Berkey-Colortran 3 cell far cyc @ 500w per circuit

2-Data flash strobes w 3 channel DMX control

2-2000w Strong Super Trouper II spotlights (located in Follow Spot Booth)

Road Power:           Located Up Stage Right 50’ from centerline. 208 Volt, 3 Phase, 5 Wire, 800 Amp fused disconnect, with 1 set 400 Amp female cam-lock tails.                   

House Lights:         May be addressed via DMX or by manual operation.

Work Lights:            3 circuits w/ 2 500 w halogen fixtures each, accessible from lighting booth or down right Stage manager’s panel.

 

 

 

House Sound Information

Mixer:                        Allen and Heath mix wizard 16 (16x3)

EQ:                             Yamaha Q2031A

Speakers:                6- Ramsa WSA 200 / 4- Mackie SR1530 15" Three-way Active Loudspeaker / 2-Mackie SWA1801 18” Active Subwoofer System / 2 SRM450 12” Two-way Loudspeaker (balcony fill)

CD:                             Dennon dual CD deck

Microphones:          2-Shure Beta SM58, 3-Shure SM58, 3-Shure SM57, 2 PCC floor mics, and 2 Senheiser e-100 series handheld wireless mics.  The system is designed for a speaking voice and moderate music playback.  Higher volume levels require that a sound system be brought in.

Mix and lighting positions: Located at the rear of the Orchestra 87’ from the edge of the stage.  Each position must be reached with a minimum of 250’ of cable from the stage. 

Clear-Com, Dressing Room and Booth Monitors, Hearing Assist (Required)

                        Road Power:           Located Down Stage Left Approximately 50’ from Centerline. 208 Volt, 3 Phase, 5 wire, 200 Amp, Fused disconnect, Female Cam-lock tie ins.

 

 

 


Line Sets Schedule:

Fly System: Double-Purchase, wire guide.  20,000 lbs. available counterweight.   

All line sets are 66’ long. Out trim is approximately 58’

LINE SET

ARBOR CAP (LBS)

DISTANCE/PLASTER LINE

NOTES

Fire Curtain

 

May not be blocked

Hemp Set

 

10”

Main Valance

1

 

1’-4”

Main Traveler

2

1400

2’-10”

 

3

1400

3’-7”

 

4

1400

4’-2”

 

5

1400

4’-10”

 

6

1400

5’-8”

 

7

1400

6’-3”

 

8

1400

6’-10”

 

9

1400

7’-6”

 

10

1400

8’-1”

 

11

1400

8’-9”

 

12

1400

9’-6”

 

13

1400

10’-5”

 

14

1400

11’-1”

 

15

1400

11’-7”

 

16

1400

12’-5”

 

17

1400

13’-2”

 

18

1400

13’-8”

 

19

1400

14’-3”

 

20

1400

14’-10”

 

21

1400

15’-11”

 

22

1400

17’-3”

 

23

1400

17’-9”

 

24

1400

18’-6”

 

25

1400

18’-10”

 

26

1400

19’-7”

 

27

1400

20’-3”

 

28

1400

21’-0”

 

29

1400

21’-8”

 

30

1400

22’-4”

 

31

1400

23’-0”

 

32

1400

23’-8”

 

33

1400

24’-7”

 

34

1400

25’-2”

 

35

1400

25’-10”

 

36

1400

26’-6”

 

37

1400

27’-0”

 

38

1400

27’-10”

 

39

1400

28’-6”

 

40

1400

29’-0

 

41

1400

29’-10”

 

42

1400

30’-4”

 

43

1400

32’-10”